• 35M
  • 35M
  • 35M
35M 35M 35M

Smooth Operation Hydraulic Rotary Motor , High Speed High Pressure Vickers Vane Motor

Product Details:

Place of Origin: Jiangsu, China

Brand Name: TPF

Certification: ISO9001 ,CE Certification

Model Number: 35M

Payment & Shipping Terms:

Minimum Order Quantity: 20pcs

Price: negotiation

Packaging Details: Plywood cases

Delivery Time: 25-35 days after order

Payment Terms: 30% pay down ,70% pay before shipping

Supply Ability: 30000pcs/month

Detailed Product Description

Product Name: High Speed Hydraulic Vane Motor Mode: 35M Series
Oil Ports: Side Ports Displacement: 80-115cc
Flange: Rhomb -flange Material: Cast Iron
Color: Blue, Grey Or Black Net Weight: 29kgs
Speed: 2700ml.r
High Light:

Single Vane Pump

Double Vane Pump


Hydraulic Vane Motor 35M Replacement Vickers Vane Motor 

High-speed, high-pressure Eaton M Series vane motors are field-proven to provide years of successful operation in elevator scraper drives, hydrostatic drives and many more auxiliary applications. They feature inlet/outlet ports that can be pressurized simultaneously while maintaining smooth operatio

Specifications:

Model Torque
Nm/6,9 bar
(lb in/ 100 psi
Displacement
cm3/r(in3/r)
Flow
L/min(USgpm)
Maximum speed
r/min
Maximum Pressure
bar
Weight (kgs)
25M 4,7 (42) 43,9 (2.68) 52,6 (13.9) 3600
4000
2600
3000
34
34
155
172
18
6,2 (55) 57,7 (3.52) 69,3 (18.3)
7,3 (65) 68,7 (4.19) 82,5 (21.8)
35M 9,0 (80) 83,6 (5.10) 100,3 (26.5) 29
10,7 (95) 100,3 (6.12) 120,4 (31.8)
13,0 (115) 121,9 (7.44) 146,1(38.6)
         

  Mounting Data :

Smooth Operation Hydraulic Rotary Motor , High Speed High Pressure Vickers Vane Motor 0Smooth Operation Hydraulic Rotary Motor , High Speed High Pressure Vickers Vane Motor 1
 
 
 Code :25M-65A-11C-20-**
 
1 Series
Standard bearing: 25M 35M 45M 50M
Heavy duty bearing: 26M 36M 46M 51M
 
2 Vane motor
 
3 Ring size - Nominal torque rating
(lb.in./100 psi)
25M: 42, 55 or 65
35M: 80, 95 or 115
45M: 130, 155 or 185
50M: 220, 255 or 300
 
4 Mountingflange & port connections
A – SAE type 2-bolt mountingflange and SAE 4-boltflange connections
 
5 Shaft
11 -Straight keyed
1 – Splined
 
6 Coverposition
(Viewing cover end)
A – Cover port opposite body port
B –Cover port 90oCCWfrom body port
C – Port connections in line
D –Cover port 90oCW from body port
 
7 design
Subject to change. Installation dimensions remainthe same for designs –20 through –29.
 
8 Special features suffix
 
50M only 114
124

NOTE: For internal drain, side port, foot mount, case drain, and other options, contact your Vickers representative.


Wechat QR code Close
the qr code